What was found
PIT - FOUND CORROSION ON STRAP AND SHEAR WEB 10 INCHES BY 10 INCHES, CENTER LINE BEAM 1016. REPLACED SHEAR WEB AND STRAPS PER SRM 51-40. CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND CORROSION ON STRAP AND SHEAR WEB 10 INCHES BY 10 INCHES, CENTER LINE BEAM 1016. REPLACED SHEAR WEB AND STRAPS PER SRM 51-40. CORROSION LEVEL 2. (M)