What was found
PIT - FOUND FRAME CORRODED 3 INCHES BY 4 INCHES, STATION 1006L STRINGER 18 AND 19 BELTFRAME. REPLACED FRAME CUTOUT AND INSTALLED DOUBLER PER EA 55673, SRM 53-00-07. CORROSION LEVEL 2, TASK NR C53-202-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FRAME CORRODED 3 INCHES BY 4 INCHES, STATION 1006L STRINGER 18 AND 19 BELTFRAME. REPLACED FRAME CUTOUT AND INSTALLED DOUBLER PER EA 55673, SRM 53-00-07. CORROSION LEVEL 2, TASK NR C53-202-01. (M)