What was found
CLT - FOUND BEAM CORRODED 1 INCH BY 1 INCH, 6 AREAS, STATION 947 FLOORBOARD HOLES. REPAIRED BEAM PER SRM 53-10-9. CORROSION LEVEL 1. REPAIRED BEAM PER SRM 53-10-9. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.