What was found
CLT - FOUND FLOORBEAM CORRODED 2 INCHES, STATION 344, LBL 36. FABRICATED T-CAP PER REPAIR DOCUMENT 53-10-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED 2 INCHES, STATION 344, LBL 36. FABRICATED T-CAP PER REPAIR DOCUMENT 53-10-51. (M)