What was found
PIT - FOUND TWO HOLES IN SKIN .75 INCH BY .5 INCH AND .5 INCH BY .25 INCH, RT SIDE STATION 29959 AFT OF APU EXHAUST. REPAIRED PER SRM 53-00-02, INSTALLED REPAIR DOUBLER. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND TWO HOLES IN SKIN .75 INCH BY .5 INCH AND .5 INCH BY .25 INCH, RT SIDE STATION 29959 AFT OF APU EXHAUST. REPAIRED PER SRM 53-00-02, INSTALLED REPAIR DOUBLER. (M)