What was found
PIT - FOUND FITTING CORRODED 2 INCHES BY 2 INCHES, NR 7 RUDDER HINGE SEGMENT MOUNT FITTING AT STATION 299.25. FRETTING CORROSION, LEVEL 1. REMOVED CORROSION, ROTO PEENED, TREATED AND PRIMED PER SRM 55-30-90, 51-20-01 AND SPM 20-14-20. (M)