What was found
CLT - FOUND FLOORBEAM T-CAP CORRODED 1 INCH BY 1 INCH AREA, STATION 947. CORROSION LEVEL 2, C53-107-02. REMOVED DAMAGE SPLICED IN T-CAP PER TR 53-60-02A. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM T-CAP CORRODED 1 INCH BY 1 INCH AREA, STATION 947. CORROSION LEVEL 2, C53-107-02. REMOVED DAMAGE SPLICED IN T-CAP PER TR 53-60-02A. (M)