What was found
CLT - FOUND FLOORBEAM T-CAP CORRODED 3 INCHES BY 6 INCHES, STATION 986.5 FULL LENGTH OF BEAM. INSTALLED NEW T-CAP, SPLICE ANGLE AND STRAP PER SRM 53-00-51. CORROSION LEVEL 2, C53-107-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM T-CAP CORRODED 3 INCHES BY 6 INCHES, STATION 986.5 FULL LENGTH OF BEAM. INSTALLED NEW T-CAP, SPLICE ANGLE AND STRAP PER SRM 53-00-51. CORROSION LEVEL 2, C53-107-02. (M)