What was found
CLT - FOUND FRAME CORRODED 2 INCHES BY 6 INCHES, STATION 787 PLUS 6 AFT CARGO DOOR FRAME. CORROSION LEVEL 1, C53-208-01. INSTALLED DOUBLER PER SRM 51-70-11 AND 53-00-07 FIG 201. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FRAME CORRODED 2 INCHES BY 6 INCHES, STATION 787 PLUS 6 AFT CARGO DOOR FRAME. CORROSION LEVEL 1, C53-208-01. INSTALLED DOUBLER PER SRM 51-70-11 AND 53-00-07 FIG 201. (M)