What was found
PIT - FOUND STRINGER CORRODED 2 INCHES BY 6 INCHES, STRINGER 28R BETWEEN BS 312 AND BS 323.7. SPLICED IN NEW STRINGER PER SRM 53-00-03 AND EA 55710. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND STRINGER CORRODED 2 INCHES BY 6 INCHES, STRINGER 28R BETWEEN BS 312 AND BS 323.7. SPLICED IN NEW STRINGER PER SRM 53-00-03 AND EA 55710. (M)