What was found
CLT - FOUND FLOORBEAM CORRODED .0500 INCH, BS 967, LBL 18.5. INSTALLED REPAIR ANGLES PER SRM 53-10-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED .0500 INCH, BS 967, LBL 18.5. INSTALLED REPAIR ANGLES PER SRM 53-10-51. (M)