What was found
PIT - FOUND BELTFRAME CRACKED .25 INCH THREE PLACES, STATION 617, LONGERON 27R. STOP DRILLED 2 CRACKS AND ROUTED OUT 2. FABRICATED AND INSTALL REPAIR ANGLE PER EA 56203. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND BELTFRAME CRACKED .25 INCH THREE PLACES, STATION 617, LONGERON 27R. STOP DRILLED 2 CRACKS AND ROUTED OUT 2. FABRICATED AND INSTALL REPAIR ANGLE PER EA 56203. (M)