What was found
PIT - FOUND Z-ANGLE CORRODED 3 INCHES IN DIAMETER, SERVICE DOOR Z-ANGLE 10 INCHES AFT STATION 986. CORROSION LEVEL 1, TASK NR C53-107-02. REMOVED CORROSION, BLENDED GOUGE, TREATED AND PRIMED PER SRM 51-20-02 AND 53-60-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND Z-ANGLE CORRODED 3 INCHES IN DIAMETER, SERVICE DOOR Z-ANGLE 10 INCHES AFT STATION 986. CORROSION LEVEL 1, TASK NR C53-107-02. REMOVED CORROSION, BLENDED GOUGE, TREATED AND PRIMED PER SRM 51-20-02 AND 53-60-51. (M)