What was found
CLT - FOUND FLOORBEAM CORRODED 5 INCHES BY .25 INCH, BS 328M 11.5 INCHES IN FROM FORWARD SERVICE DOOR. INSTALLED REPAIR ANGLES, T-CAP PER SRM 53-00-51 FOG 201. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED 5 INCHES BY .25 INCH, BS 328M 11.5 INCHES IN FROM FORWARD SERVICE DOOR. INSTALLED REPAIR ANGLES, T-CAP PER SRM 53-00-51 FOG 201. (M)