What was found
PIT - FOUND CUSP MEMBRANE 1 INCH BY 4 INCH AREA CORRODED, RIGHT CUSP SUBFLOOR AT FRAME FITTING, STATION 237. INSTALLED NEW SECTION OF MANUFACTURE CUSP MEMBRANE OUT OF 7075-T6 .32 INCH PER EA 56223 AND SRM 53-05 FIG 96. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND CUSP MEMBRANE 1 INCH BY 4 INCH AREA CORRODED, RIGHT CUSP SUBFLOOR AT FRAME FITTING, STATION 237. INSTALLED NEW SECTION OF MANUFACTURE CUSP MEMBRANE OUT OF 7075-T6 .32 INCH PER EA 56223 AND SRM 53-05 FIG 96. (M)