What was found
PIT - FOUND Z-ANGLE CORRODED 1 INCH BY 1 INCH, STATION 950 AFT ENTRY DOOR TOP SURFACE. CORROSION LEVEL 1, TASK NR C53-107-02. DEFECTIVE PART REPLACED WITH IDENTICAL PART NR PER SRM 53-60-51 AND 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND Z-ANGLE CORRODED 1 INCH BY 1 INCH, STATION 950 AFT ENTRY DOOR TOP SURFACE. CORROSION LEVEL 1, TASK NR C53-107-02. DEFECTIVE PART REPLACED WITH IDENTICAL PART NR PER SRM 53-60-51 AND 51-40-02. (M)