What was found
PIT - FOUND Z-ANGLE CRACKED .5 INCH IN DIAMETER, STATION 967 TO 986 AFT SERVICE DOOR SILL. CORROSION LEVEL 1, TASK NR C53-107-02. REMOVED CORROSION, TREATED AND PRIMED. INSTALLED NEW NUT PLATES PER SRM 51-10-02, 53-60-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND Z-ANGLE CRACKED .5 INCH IN DIAMETER, STATION 967 TO 986 AFT SERVICE DOOR SILL. CORROSION LEVEL 1, TASK NR C53-107-02. REMOVED CORROSION, TREATED AND PRIMED. INSTALLED NEW NUT PLATES PER SRM 51-10-02, 53-60-51. (M)