What was found
PIT - FOUND FLOORBEAM CORRODED 1 INCH IN DIAMETER, STATION 186 FLOORBEAM BB10 LOWER LEG TOP SURF NUTPLATE. REMOVED NUTPLATE AND CORROSION. TREATED, PRIMED AND INSTALLED NUTPLATE PER SRM 51-10-02, 51-20-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOORBEAM CORRODED 1 INCH IN DIAMETER, STATION 186 FLOORBEAM BB10 LOWER LEG TOP SURF NUTPLATE. REMOVED NUTPLATE AND CORROSION. TREATED, PRIMED AND INSTALLED NUTPLATE PER SRM 51-10-02, 51-20-01. (M)