What was found
TPA - FOUND STRINGER CORRODED 6 INCHES, STRINGER 27L FROM 1016 TO 986.5. INSTALLED NEW SECTION PER SRM 53-10-3 FIG 1 SHEET 7. CORROSION LEVEL 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TPA - FOUND STRINGER CORRODED 6 INCHES, STRINGER 27L FROM 1016 TO 986.5. INSTALLED NEW SECTION PER SRM 53-10-3 FIG 1 SHEET 7. CORROSION LEVEL 1. (M)