What was found
PIT - FOUND STRINGER CORRODED 1 INCH BY 6 INCHES, BS 440 BETWEEN STRINGER 24R AND 25R UNDER NUTPLATES. REMOVED CORROSION, TREATED, PRIMED PER SRM 51-10-02 AND 52-20-101. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND STRINGER CORRODED 1 INCH BY 6 INCHES, BS 440 BETWEEN STRINGER 24R AND 25R UNDER NUTPLATES. REMOVED CORROSION, TREATED, PRIMED PER SRM 51-10-02 AND 52-20-101. (M)