What was found
PIT - FOUND STRINGER CORRODED 1 INCH BY 10 INCHES, UNDER NUTPLATES ON FRAME 500D STRINGER 18R-26R. CORROSION LEVEL 1. REMOVED CORROSION, TREATED AND PRIMED PER SRM 51-20-04. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND STRINGER CORRODED 1 INCH BY 10 INCHES, UNDER NUTPLATES ON FRAME 500D STRINGER 18R-26R. CORROSION LEVEL 1. REMOVED CORROSION, TREATED AND PRIMED PER SRM 51-20-04. (M)