What was found
CLT - DURING Q-4 INSPECTION, FOUND DOOR FRAME CRACKED .500 INCH AT INBOARD UPPER FORWARD CORNER R-1. FABRICATED SPLICE AND INSTALLED PER SRM 51-40-02. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-4 INSPECTION, FOUND DOOR FRAME CRACKED .500 INCH AT INBOARD UPPER FORWARD CORNER R-1. FABRICATED SPLICE AND INSTALLED PER SRM 51-40-02. (X)