What was found
CLT - FOUND VERTICAL STIFFENER CRACKED 1 INCH, INBOARD FLANGE LBL 5.7 VERT STIFFENER STATION 178 WL 184. INSTALLED 1/2 HARD SS ANGLES PER SRM 53-10-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND VERTICAL STIFFENER CRACKED 1 INCH, INBOARD FLANGE LBL 5.7 VERT STIFFENER STATION 178 WL 184. INSTALLED 1/2 HARD SS ANGLES PER SRM 53-10-11. (M)