What was found
CLT - FOUND FLOORBEAM CORRODED 1 INCH BY 1 INCH, BS 947, RBL 50 - LBL 44. REPAIRED T-CAP PER SRM 53-10-09. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED 1 INCH BY 1 INCH, BS 947, RBL 50 - LBL 44. REPAIRED T-CAP PER SRM 53-10-09. (M)