What was found
CLT - Q-4, CREASE BEAM HAD 3 INCH CRACK AT FORWARD END OF S17R STA 617. FABRICATED REPAIR ANGLES PER SRM 53-60-13. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - Q-4, CREASE BEAM HAD 3 INCH CRACK AT FORWARD END OF S17R STA 617. FABRICATED REPAIR ANGLES PER SRM 53-60-13. (X)