What was found
CLT - FOUND CREASE BEAM WEB CORRODED 1 INCH BY 2 INCHES IN 6 PLACES, BETWEEN STATION 847-867 STRINGER 17L. CORROSION LEVEL 1, TASK NR C53-107-01. DEFECTIVE PART REPLACED WITH IDENTICAL PART NR PER SRM 51-10-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND CREASE BEAM WEB CORRODED 1 INCH BY 2 INCHES IN 6 PLACES, BETWEEN STATION 847-867 STRINGER 17L. CORROSION LEVEL 1, TASK NR C53-107-01. DEFECTIVE PART REPLACED WITH IDENTICAL PART NR PER SRM 51-10-2. (M)