What was found
CLT - FOUND FLOORBEAM CRACKED 1 INCH BY 10 INCHES, STATION 312 BETWEEN LBL 30 AND RBL 12. CORROSION LEVEL 1. INSTALLED UPPER CHORD REPAIRED T-CAP PER SRM 53-10-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CRACKED 1 INCH BY 10 INCHES, STATION 312 BETWEEN LBL 30 AND RBL 12. CORROSION LEVEL 1. INSTALLED UPPER CHORD REPAIRED T-CAP PER SRM 53-10-51. (M)