What was found
CLT - FOUND FLOORBEAM CORRODED 1 INCH BY 1 INCH IN FOUR PLACES, STATION 947.5 RBL 4, 5, 10.5 AND LBL 5. CORROSION LEVEL 1. SPLICED T-CAP PER SRM 53-10-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED 1 INCH BY 1 INCH IN FOUR PLACES, STATION 947.5 RBL 4, 5, 10.5 AND LBL 5. CORROSION LEVEL 1. SPLICED T-CAP PER SRM 53-10-2. (M)