What was found
CLT - FOUND FRAME CRACKED .375 INCH, STATION 312, BETWEEN STRINGER 5 AND STRINGER 6L. REPAIRED PER SRM 51-40-3 AND 20-30-06. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FRAME CRACKED .375 INCH, STATION 312, BETWEEN STRINGER 5 AND STRINGER 6L. REPAIRED PER SRM 51-40-3 AND 20-30-06. (M)