What was found
CLT - FOUND VERTICAL ANGLE CRACKED .750 INCH, 663 BULKHEAD, RBL 45 INCHES AND 10 INCHES DOWN FROM CEILING. FABRICATED NEW STIFFENER AND INSTALLED PER SRM 51-10-1 AND DWG 6545409. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND VERTICAL ANGLE CRACKED .750 INCH, 663 BULKHEAD, RBL 45 INCHES AND 10 INCHES DOWN FROM CEILING. FABRICATED NEW STIFFENER AND INSTALLED PER SRM 51-10-1 AND DWG 6545409. (M)