What was found
CLT - FOUND FLOORBEAM CORRODED 2 INCHES BY 2 INCHES AND 1 FT BY 2 INCHES, STATION 1006 TO 1016, LBL 5.5 TO 9. REMOVED AND REPLACED PER SRM 51-30-00. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED 2 INCHES BY 2 INCHES AND 1 FT BY 2 INCHES, STATION 1006 TO 1016, LBL 5.5 TO 9. REMOVED AND REPLACED PER SRM 51-30-00. (M)