CLT - FOUND FLOORBEAM CORRODED 2 INCHES BY 3 INCHES, BL 0 STATION 312 CABIN FLOORBEAM LBL 18 - RBL 18. INSTALLED SPLICE ANGLES EPR SRM 52-10-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED 2 INCHES BY 3 INCHES, BL 0 STATION 312 CABIN FLOORBEAM LBL 18 - RBL 18. INSTALLED SPLICE ANGLES EPR SRM 52-10-51. (M)