What was found
CLT - FOUND FLOORBEAM CORRODED .5 INCH BY 1 INCH, STATION 947 FROM LBL 12 THROUGH RBL 12 TOP SURFACE. INSTALLED NEW SECTION PER TR 53-60-02 REV A. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED .5 INCH BY 1 INCH, STATION 947 FROM LBL 12 THROUGH RBL 12 TOP SURFACE. INSTALLED NEW SECTION PER TR 53-60-02 REV A. (M)