What was found
CLT - FOUND FLOOR SUPPORT CORRODED 1 INCH BY 1 INCH, BETWEEN FLOORBEAM 947 AND 967 AT RBL 16. INSTALLED NEW PART PER SRM 51-10-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOOR SUPPORT CORRODED 1 INCH BY 1 INCH, BETWEEN FLOORBEAM 947 AND 967 AT RBL 16. INSTALLED NEW PART PER SRM 51-10-2. (M)