What was found
CLT - FOUND FLOORBEAM TOP FLANGE CORRODED 1 INCH, STATION 1640, LBL 15 TO RBL 36, WL 208. CORROSION LEVEL 1. INSTALLED FABRICATED T-CAP PER SRM 53-00-51 AND TR 53-15-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM TOP FLANGE CORRODED 1 INCH, STATION 1640, LBL 15 TO RBL 36, WL 208. CORROSION LEVEL 1. INSTALLED FABRICATED T-CAP PER SRM 53-00-51 AND TR 53-15-01. (M)