What was found
FOUND L ANGLE CORRODED .5 INCH BY .75 INCH, STATION 1716, LBL 34 TO LBL 40. FABRICATED AND INSTALLED NEW L-ANGLE PER SRM 51-10-00. CORROSION LEVEL 2 C 53-251-03. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND L ANGLE CORRODED .5 INCH BY .75 INCH, STATION 1716, LBL 34 TO LBL 40. FABRICATED AND INSTALLED NEW L-ANGLE PER SRM 51-10-00. CORROSION LEVEL 2 C 53-251-03. (M)