What was found
PIT - FOUND LONGERON CORRODED 6 INCHES BY 2 INCHES, STATION 503 LONGERON 30. CORROSION LEVEL 1 TASK NR C51-53300. INSTALLED SPLICE PER SRM 53-02 FIG 18. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND LONGERON CORRODED 6 INCHES BY 2 INCHES, STATION 503 LONGERON 30. CORROSION LEVEL 1 TASK NR C51-53300. INSTALLED SPLICE PER SRM 53-02 FIG 18. (M)