What was found
PIT - FOUND FRAME CRACKED .25 INCH, FS 663.75 AT CUTOUT FOR NR 1 STRINGER. INSTALLED REPAIR PER SRM 53-00-07 FIG 207 SHT 6. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FRAME CRACKED .25 INCH, FS 663.75 AT CUTOUT FOR NR 1 STRINGER. INSTALLED REPAIR PER SRM 53-00-07 FIG 207 SHT 6. (M)