What was found
CLT - FOUND FLANGE CRACKED IN 4 PLACES, ONE AT 1 INCH AND 3 AT 4 INCHES, UPPER FLANGE INTERCOSTAL STATION 380 TO 400 BL 0. FABRICATED NEW UPPER FLANGE AND INSTALLED PER SRM 51-10-2, 51-20-01 AND 53-30-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLANGE CRACKED IN 4 PLACES, ONE AT 1 INCH AND 3 AT 4 INCHES, UPPER FLANGE INTERCOSTAL STATION 380 TO 400 BL 0. FABRICATED NEW UPPER FLANGE AND INSTALLED PER SRM 51-10-2, 51-20-01 AND 53-30-51. (M)