What was found
CLT - FOUND INTERCOSTAL CORRODED 3 INCHES BY 6 INCHES, GALLEY FLOOR WIDGET BS 370 AT RBL 11. REMOVED AND REPLACED INTERCOSTAL PER SRM 57-10-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND INTERCOSTAL CORRODED 3 INCHES BY 6 INCHES, GALLEY FLOOR WIDGET BS 370 AT RBL 11. REMOVED AND REPLACED INTERCOSTAL PER SRM 57-10-02. (M)