What was found
PIT - FOUND FITTINGS CORRODED .75 INCH BY 1 INCH, STRINGER FITTINGS STATION 1016 STRINGER 23L, 24L, 25L. CORROSION LEVEL 1 TASK NR C53-701-01. CLEANED CORROSION, TREATED AND PRIMED. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FITTINGS CORRODED .75 INCH BY 1 INCH, STRINGER FITTINGS STATION 1016 STRINGER 23L, 24L, 25L. CORROSION LEVEL 1 TASK NR C53-701-01. CLEANED CORROSION, TREATED AND PRIMED. (M)