What was found
PIT - FOUND BEAM CORRODED 2 INCHES BY .75 INCHES, RIGHT LAVATORY FLOORBEAM STATION 1322. INSTALLED ANGLE PER SRM 53-05 FIG 20A. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND BEAM CORRODED 2 INCHES BY .75 INCHES, RIGHT LAVATORY FLOORBEAM STATION 1322. INSTALLED ANGLE PER SRM 53-05 FIG 20A. (M)