What was found
CLT - FOUND FLOORBEAM CRACKED 1 INCH BY 1 INCH, UPPER FLANGE FLOORBEAM STATION 312, RBL 7 TO 8. CORROSION LEVEL 1 C53-107-01. INSTALLED NEW T-CAP PER SRM 53-10-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CRACKED 1 INCH BY 1 INCH, UPPER FLANGE FLOORBEAM STATION 312, RBL 7 TO 8. CORROSION LEVEL 1 C53-107-01. INSTALLED NEW T-CAP PER SRM 53-10-51. (M)