What was found
CLT - FOUND FLOORBEAM CRACKED 1 INCH BY 1 INCH, STATION 344, LBL 9. CORROSION LEVEL 1. REMOVED T-CAP AND FABRICATED NEW T-CAP AND SPLICE PER SRM 53-10-51 AND 53-40-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CRACKED 1 INCH BY 1 INCH, STATION 344, LBL 9. CORROSION LEVEL 1. REMOVED T-CAP AND FABRICATED NEW T-CAP AND SPLICE PER SRM 53-10-51 AND 53-40-51. (M)