What was found
CLT - FOUND FLOORBEAM CORRODED 2 INCHES BY .5 INCHES, BS 967, LBL 14-18. CORROSION LEVEL 1 C53-107-02. INSTALLED LEG REPAIR AND DOUBLER PER SRM 53-60-51 FIG 203. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED 2 INCHES BY .5 INCHES, BS 967, LBL 14-18. CORROSION LEVEL 1 C53-107-02. INSTALLED LEG REPAIR AND DOUBLER PER SRM 53-60-51 FIG 203. (M)