What was found
CLT - FOUND FRAME CRACKED .500 INCH, BS 907 BETWEEN STRINGER 8R AND 9R AND 8L AND 9L. INSTALLED DOUBLER PER TR 53-10-14 AND SRM 53-00-07 FIG 202. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FRAME CRACKED .500 INCH, BS 907 BETWEEN STRINGER 8R AND 9R AND 8L AND 9L. INSTALLED DOUBLER PER TR 53-10-14 AND SRM 53-00-07 FIG 202. (M)