What was found
CLT - FOUND STRINGER CORRODED 1 INCH BY 4 INCHES, STATION 520 TO 526 JUST ABOVE STRINGER 28L. INSTALLED STEEL REPAIR ANGLE PER EA 68919. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND STRINGER CORRODED 1 INCH BY 4 INCHES, STATION 520 TO 526 JUST ABOVE STRINGER 28L. INSTALLED STEEL REPAIR ANGLE PER EA 68919. (M)