What was found
CLT - FOUND STRINGER CORRODED .5 INCH BY 4 INCHES, BS 500F PLUS 13 INCHES TO 17 INCHES, STRINGER 26L OUTBOARD UPPER FLANGE. REPAIRED PER SRM 53-00-03. CORROSION LEVEL 1 C53-208-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND STRINGER CORRODED .5 INCH BY 4 INCHES, BS 500F PLUS 13 INCHES TO 17 INCHES, STRINGER 26L OUTBOARD UPPER FLANGE. REPAIRED PER SRM 53-00-03. CORROSION LEVEL 1 C53-208-01. (M)