What was found
CLT - FOUND STRINGER CORRODED 2 INCHES BY 6 INCHES, AFT CARGO STATION 1380-1400, RBL 8. INSTALLED NEW STRINGER SECTION PER SRM 51-10-01. CORROSION LEVEL 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND STRINGER CORRODED 2 INCHES BY 6 INCHES, AFT CARGO STATION 1380-1400, RBL 8. INSTALLED NEW STRINGER SECTION PER SRM 51-10-01. CORROSION LEVEL 1. (M)