What was found
PIT - FOUND FITTING BUSHING DAMAGE, RIGHT HORIZONTAL STAB FORWARD CENTER SECTION, TOP AFT CLEVIS FITTING. CORROSION LEVEL 1. MACHINED FORWARD FACE OF LUG REMOVED .014 INCH PER SRM 55-10-10, MFG NEW BUSHING PER SRM 55-10-10. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FITTING BUSHING DAMAGE, RIGHT HORIZONTAL STAB FORWARD CENTER SECTION, TOP AFT CLEVIS FITTING. CORROSION LEVEL 1. MACHINED FORWARD FACE OF LUG REMOVED .014 INCH PER SRM 55-10-10, MFG NEW BUSHING PER SRM 55-10-10. (M)